Product Description
Lightning Counter Action Tester 

Darui Electric recommends for you:

Lightning Counter Action Tester Usage Method:



1. Please charge before use. To ensure charging effect and extend battery life, use the dedicated charger. It takes about 3-4 hours to fully charge an empty battery. The red light on the charger indicates charging; the green light indicates charging is complete.



2. According to the installation height of the counter, appropriately extend the telescopic discharge rod.



3. For the dedicated grounding wire, insert one end plug into the jack at the rear of the calibrator, and connect the other end clip to the ground.



4. Press the red button to turn on high voltage for about 1 second. The indicator light will light up (flickering slightly),



then you can gently click the connection end of the counter and the arrester for testing.



5. After each click, the discharge rod tip should leave the counter. If repeated testing is needed, do not release the button. Wait for 1-2 seconds until the indicator light flickers again, then click again for testing.



6. Continuous testing will cause the calibrator to heat up. Please pay attention to appropriate intervals to reduce failures and extend battery life.



7. The calibrator output has three levels: high, medium, and low, which can be adjusted through the toggle switch on the head to adapt to testing different types or brands of counters.



8. If the indicator light does not flash after pressing the button for more than 3 seconds, it indicates that the battery needs charging.



9. Do not disassemble the calibrator arbitrarily. If the battery pack capacity significantly decreases or charging efficiency is too low, it needs replacement. Please purchase the dedicated battery pack from our company.



Features:



1.  Built-in dedicated Ni-H rechargeable battery pack with large capacity, can test up to 300 times after full charge.



2.  Short test interval (about 1 second), and it does not extend as the battery level decreases.



3.  Output has three adjustable levels: high, medium, and low, suitable for the action verification of different types and brands of lightning counters.



4.  Rechargeable, completely eliminating the trouble of frequent battery replacement or damage caused by battery leakage.



5.  Small size, light weight, easy to carry.



Technical Parameters:



Output Voltage: 0~1200V adjustable         Capacitance: 10μF



Action Time: 1~2 seconds/time   Power Supply: DC 4.5V*2 pieces



LCD Display: 9V       Dimensions: 200×115×45mm




Note: The above information and technical parameters are compiled and released by Yangzhou Darui Electric Co., Ltd.
WeChat QR Code
💬
💬 Message

Hello! Have you found what you need? Contact us directly online!

Leave a Message for Consultation
Yangzhou Darui Electric Co., Ltd.
主营产品:Dielectric Loss Tester、Transformer Ratio测试仪、Loop Resistance Tester、高压None线核相仪、Insulation Resistance Tester、Partial Discharge Tester、Cable Fault Tester、DC Resistance Tester等。
☎ Phone: 18952707000(关经理)📞 Landline: 0514-88770377✉ Email: 195214804@qq.com
Verification Code
By submitting, you agree to ourTerms of ServiceandPrivacy Policy
🏠 网站Home📞 一键拨号✉ Contact Us