Product Description
Mine Stray Electricity Leakage Tester 

Darui Electric recommends for you:


 The Mine Stray Current Tester is a portable rectifier instrument with high sensitivity and multi-range protection circuits.

I. Purpose of the Mine Stray Current TesterThe Mine Stray Current Tester is a portable rectifier instrument with high sensitivity and multi-range protection circuits. Its characteristics are: wide measurement range, with a total of twenty ranges, capable of measuring AC/DC stray voltage and stray current separately, requiring no power supply itself, safe and reliable. It is suitable for testing the current and voltage generated by steel rails, water pipes, cables, etc. in underground coal mines, preventing premature detonation of electric detonators and other combustion and explosion accidents caused by stray current discharge, minimizing fire sources in mines.

II. Performance of the Mine Stray Current Tester: Measurement Range and Accuracy Class

Measurement Range Measurement Accuracy Remarks  
Current Range 0-50mA-250mA
-1A-5A-10A
AC ±5% DC ±2.5% Before use, the pointer must be adjusted to zero position, i.e., zero adjustment.
Voltage Range 0-0.2V-1V
-4V-20V-40V
   

III. Usage Methods and Precautions for the Mine Stray Current Tester1. Before measurement, screw the test lead connectors onto the two binding posts respectively, and adjust the meter pointer to the zero scale line. 2. Place the test leads connected to the binding posts on the two points to be measured (e.g., steel rails, water pipes, cable sheaths, coal, ground, etc.). The two test points should be on different conductors, with a distance of about 2 meters. Normally, measure every 50-100 meters, or determine test points temporarily as needed. Set the range switch to the appropriate position, and the meter reading, after conversion, gives the corresponding current value. 3. During measurement, ensure the hard alloy tip of the measuring probe makes good contact with the object under test, and the instrument should be placed horizontally to ensure accurate readings. 4. When AC stray current cannot be measured at a location, also test for DC stray current, and vice versa. 5. When measuring stray voltage values, the corresponding ranges are: 50mA corresponds to 0.2V, 250mA to 1V, 1A to 4V, 5A to 20V, 10A to 40V. (i.e., current value multiplied by 4 gives the voltage value) 6. When the magnitude of stray current is unknown, first set to the maximum range, then gradually decrease to the appropriate measuring range. 7. When the measured current exceeds 5A, the instrument should only be used for short-time measurements; when the measured current exceeds 10A, the instrument should only be used for instantaneous measurements, to avoid burning out components and the instrument with high current. 8. When measuring DC stray current, if the meter pointer deflects in the reverse direction, swap the test leads. 9. When the instrument is not in use, set it to the "Off" position.



Note: The above information and technical parameters are compiled and released by Yangzhou Darui Electric Co., Ltd.
WeChat QR Code
💬
💬 Message

Hello! Have you found what you need? Contact us directly online!

Leave a Message for Consultation
Yangzhou Darui Electric Co., Ltd.
主营产品:Dielectric Loss Tester、Transformer Ratio测试仪、Loop Resistance Tester、高压None线核相仪、Insulation Resistance Tester、Partial Discharge Tester、Cable Fault Tester、DC Resistance Tester等。
☎ Phone: 18952707000(关经理)📞 Landline: 0514-88770377✉ Email: 195214804@qq.com
Verification Code
By submitting, you agree to ourTerms of ServiceandPrivacy Policy
🏠 网站Home📞 一键拨号✉ Contact Us