全自动Dielectric Loss Tester-扬州达瑞

Dual-Angle Safe Piercing Device - Yangzhou Dary

Published: 2024-07-01 12:29:29

Views: 2922

Category: Cable Fault Tester

Product Description

Dual-Angle Safe Piercing Device 


Dary Electric recommends:

1. Features




  • The dual-angle safe piercing device is suitable for piercing various power cables, ensuring safe and reliable piercing;

  • The main controller is equipped with dual guns, allowing two different angle piercings in one operation, ensuring operator safety, convenience, and speed;

  • Remote control/timed dual working modes, with dual-key confirmation to enter the working mode, ensuring operator safety;

  • Dual-key remote control (press A and B keys simultaneously), requiring both keys to be pressed at the same time for remote firing, preventing accidental single-key presses and improving remote control accuracy and safety;



★ Uses real human voice prompts synchronized with LCD display, guiding operation for safer, more accurate, and intuitive use;



★ Mechanical and electronic multiple protection designs for safety and reliability;




  • Specifically designed for piercing cables, with an attractive appearance, directly fixed onto the cable, safe and convenient, installable at any angle;

  • Powered by ordinary dry batteries, suitable for field use without external power, while ensuring complete isolation from the power system for supply safety.



2. Technical Specifications



★ Wireless remote control distance: ≤20 meters



★ Applicable cables: ≤¢125mm various power cables



★ Weight: Complete set including aluminum alloy case 15kg



★ Dimensions: 45×45×16cm³ (including aluminum alloy case and all accessories)

 



Usage Precautions



1. Operate according to the instructions above.



2. If during piercing, the bolt moves but the nail does not explode, check if item ⑿ is tightened; if loose, tighten and try again. If it still does not explode after tightening, replace the nail. If it still does not explode, contact the manufacturer.



3. If during piercing, the spring in the chamber does not move, but the control box operation is complete, it may be due to prolonged storage or poor maintenance. Loosen the bolt force adjustment nut ⑿ a few turns and perform a blank test until the spring moves once, then tighten it and continue testing. If it still does not move, contact the manufacturer.



4. Safety of this device:



<1> Electronic control ensures that even if the device is powered on and the "Confirm" key is accidentally pressed to enter the selected mode, a second confirmation or re-selection of the mode is required; the device will not automatically operate due to accidental entry into timed mode. A second confirmation is necessary to enter the selected mode.



<2> Electronic control ensures that even if the device is powered on and a key on the remote control is accidentally pressed, the device will not operate; both A and B keys on the remote must be pressed simultaneously for the device to operate.



<3> Electronic control ensures that only after the prompt to leave the area, pressing both C and D keys on the remote will activate the device.



<4> In timed mode, the remote control is ineffective, preventing accidental remote presses from causing misoperation.



5. If the display shows "Failure, check the device and try again", please contact the manufacturer promptly and do not disassemble the control box yourself.



6. If the screen shows low battery, replace the batteries promptly and remove them after each use.



7. Consumables such as nails and cartridges must be the same specifications and models as those configured at the factory.



8. When installing the piercing device, ensure the U-shaped groove of the gun head is aligned with the fixing plate to prevent damage to the U-shaped groove from the impact force during piercing.



9. After live firing, always clean the gun chamber with a brush to prevent residual debris from jamming the firing pin and causing malfunction.



10. The device is only for piercing cables, not for piercing wood sticks or other items, as the high impact force may damage the device.



Note: The above information and technical parameters are compiled and released by Yangzhou Dary Electric Co., Ltd.

WeChat QR Code
💬
💬 Message

Hello! Have you found what you need? Contact us directly online!

Leave a Message for Consultation
Yangzhou Darui Electric Co., Ltd.
主营产品:Dielectric Loss Tester、Transformer Ratio测试仪、Loop Resistance Tester、高压None线核相仪、Insulation Resistance Tester、Partial Discharge Tester、Cable Fault Tester、DC Resistance Tester等。
☎ Phone: 18952707000(关经理)📞 Landline: 0514-88770377✉ Email: 195214804@qq.com
Verification Code
By submitting, you agree to ourTerms of ServiceandPrivacy Policy
🏠 网站Home📞 一键拨号✉ Contact Us