Working Principle
Under the action of AC voltage, the dielectric consumes a portion of electrical energy, which is converted into heat energy and causes loss. This energy loss is called dielectric loss. When an AC voltage is applied to a dielectric, there is a phase angle difference Ψ between the voltage and current in the dielectric. The complementary angle δ of Ψ is called the dielectric loss angle, and the tangent of δ, tgδ, is called the dielectric loss tangent. The tgδ value is a parameter used to measure dielectric loss. The instrument's measurement circuit includes a standard circuit (Cn) and a test circuit (Cx). The standard circuit consists of a built-in high-stability standard capacitor and the measurement circuit, while the test circuit consists of the test object and the measurement circuit. The measurement circuit is composed of a sampling resistor, a preamplifier, and an A/D converter. Through the measurement circuit, the amplitudes and phases of the current in the standard circuit and the test circuit are respectively measured. Then, using a microcontroller with digital real-time sampling and vector operations, the capacitance value and dielectric loss tangent of the test object can be obtained.
The instrument has built-in anti-interference measures to ensure accurate measurement under external electric field interference.
Technical Parameters
|
1 |
Operating Conditions |
-5℃∽40℃ |
RH<80% |
||
|
2 |
Anti-interference Principle |
Frequency Conversion Method |
|||
|
3 |
Power Supply |
AC 220V±10% |
Frequency Unrestricted |
||
|
4 |
High Voltage Output |
0.5KV∽10KV |
Every 0.1kV |
||
|
Accuracy |
2% |
||||
|
Maximum Current |
200mA |
||||
|
Capacity |
1500VA |
||||
|
5 |
Self-Excited Power Supply |
AC 0V∽50V/15A |
45HZ/55HZ |
||
|
6 |
Resolution |
tgδ: 0.001% |
Cx: 0.1pF |
||
|
7 |
Accuracy |
△tgδ:±(Reading*1.0%+0.040%) |
|||
|
△C x :±(Reading*1.0%+1.0PF) |
|||||
|
8 |
Measurement Range |
tgδ |
Unrestricted |
||
|
C x |
15pF < Cx < 200nF |
||||
|
10KV |
Cx < 60 nF |
||||
|
5KV |
Cx < 100 nF |
||||
|
1KV |
Cx < 200 nF |
||||
|
CVT Test |
Cx < 200 nF |
||||
|
9 |
CVT Ratio Range |
10∽10000 |
|||
|
CVT Ratio Accuracy |
0.1% |
||||
|
CVT Ratio Resolution |
0.1 |
||||
|
10 |
Dimensions |
430(L)×330(W)×330(H) |
|||
|
11 |
Memory Size |
80 groups, supports U-disk data storage |
|||
|
12 |
Weight |
28 Kg |
|||