Correct Usage of Z-V Pocket Lightning Counter Tester 

Darui Electric recommends for you:

Correct Usage of Z-V Pocket Lightning Counter Tester



1. Please charge before use. To ensure charging effectiveness and extend battery life, use the dedicated charger. It takes about 3-4 hours to fully charge an empty battery. The red light on the charger indicates charging. 

2. According to the installation height of the counter, properly extend the telescopic discharge rod. 

3. For the dedicated grounding wire, insert one end's plug into the jack at the rear of the tester, and clamp the other end's clip to the ground. 

4. Press the red button to activate high voltage for about 1 second. When the indicator light lights up (with a slight flicker), you can gently tap the connection end between the counter and the arrester for testing. 

5. After each tap, the discharge rod tip should be removed from the counter. If repeated testing is needed, do not release the button. Wait for 1-2 seconds until the indicator light flickers again, then tap again for testing. 

6. Continuous testing may cause the tester to heat up. Please allow appropriate intervals to reduce malfunctions and extend battery life. 

7. The tester output has three levels: high, medium, and low, adjustable via the toggle switch on the head to suit testing different types or brands of counters. 

8. If the indicator light does not flash within 3 seconds after pressing the button, the battery needs charging. 

9. Do not disassemble the tester arbitrarily. If the battery pack capacity significantly drops or charging efficiency is too low, it needs replacement. Please purchase a dedicated battery pack from our factory.




Note: The above information and technical parameters are compiled and released by Yangzhou Darui Electric Co., Ltd.