Other Specifications:
Power Supply: AC 220V
Number of Testable Contacts: 6 normal contacts + 6 contacts with closing resistor
Stroke Sensor: 1 photoelectric encoder, optional resolution up to 5000 points
DC Operating Voltage Range: 20V-280V, max current 20A
External Power Input: max operating current 30A
Energy Storage Motor Drive: 48V-220Vdc, 10A
Printer: 24-dot matrix high-speed thermal printer
Computer Interface: Ethernet (LAN) + USB port
Storage Capacity: Stores 16 sets of measurement data and waveforms locally, unlimited storage when USB is connected
Display: 320×240 monochrome LCD (visible in strong outdoor light)
Operating Environment: -20℃~+55℃
Relative Humidity: ≤90%
Dimensions: 37cm X 30cm X 15cm
Weight: 4KG
Operating Environment
Input Power 220V±10% 50Hz±10% Atmospheric Pressure 86~106kPa
Temperature -20~45℃ Humidity ≤80%RH
3.2, Safety Performance
Insulation Resistance >2.0MΩ
Dielectric Strength Power supply to chassis withstands 1.5KV power frequency for 1 minute without flashover or arcing.
3.3, Basic Parameters
◆Time: Range 0-64000.0ms Resolution 0.1ms Error ≤ 0.1%rdg±0.1
◆Speed: Range 0-20.00m/s Resolution 0.01m/s Error ≤1%rdg±0.01