Other Specifications:



Power Supply: AC 220V                



Number of Testable Contacts: 6 normal contacts + 6 contacts with closing resistor



Stroke Sensor: 1 photoelectric encoder, optional resolution up to 5000 points



DC Operating Voltage Range: 20V-280V, max current 20A



External Power Input: max operating current 30A



Energy Storage Motor Drive: 48V-220Vdc, 10A



Printer: 24-dot matrix high-speed thermal printer



Computer Interface: Ethernet (LAN) + USB port



Storage Capacity: Stores 16 sets of measurement data and waveforms locally, unlimited storage when USB is connected



Display: 320×240 monochrome LCD (visible in strong outdoor light)



Operating Environment:  -20℃~+55℃



Relative Humidity: ≤90%



Dimensions: 37cm X 30cm X 15cm



Weight: 4KG

 



Operating Environment



   Input Power   220V±10%  50Hz±10%  Atmospheric Pressure   86~106kPa



   Temperature   -20~45℃     Humidity   ≤80%RH



3.2, Safety Performance



   Insulation Resistance   >2.0MΩ  



   Dielectric Strength   Power supply to chassis withstands 1.5KV power frequency for 1 minute without flashover or arcing.



3.3, Basic Parameters



◆Time: Range 0-64000.0ms  Resolution 0.1ms  Error ≤ 0.1%rdg±0.1



◆Speed: Range 0-20.00m/s  Resolution 0.01m/s  Error ≤1%rdg±0.01