Capacitor Reactive Power

0 ~ 20.00Mvar

Error Value

±1%

Capacitor Active Power

0 ~ 20.00kW

Error Value

±1%

Capacitor Dissipation Factor

0 ~ 20.00%

Error Value

±1%

Capacitor Resistance Component

0 ~ 10.00MΩ

Error Value

±1%



Inductance Measurement Range

Error Value

0.10mH ~ 0.200H

±0.5%

2.000H ~ 20.00H

±0.5%

20.00H ~ 200.0H

±0.5%

200.0H ~ 2000.H

±0.5%



Inductor Reactive Power

0 ~ 20.00Mvar

Error Value

±1%

Inductor Active Power

0 ~ 20.00kW

Error Value

±1%

Inductor Dissipation Factor

0 ~ 20.00%

Error Value

±1%

Inductor Resistance Component

0 ~ 10.00MΩ

Error Value

±1%



Clamp Sensor Measurement Range and Error (Component)



Current Measurement Range (AC)

Error Value

0.000mA ~ 50.00A

±0.2%

 



Product Features:



(1) Automatic range conversion;



(2) Stores 2000 test data;



(3) Large screen LCD (320×240 LCD) display, Chinese menu operation prompts;



(4) Realize waveform and measurement processing data display on the same screen, making the test process more intuitive;



(5) With setting, calibration and debugging functions.



 It has the advantages of small measurement workload, quick and simple operation, stable performance, accurate measurement, high fault detection rate; it can also measure the inductance of reactors, discharge resistance measurement function, measure the current and capacitance of coupling capacitors under live conditions, calculate the capacity of the measured capacitance; synchronously display voltage and current waveforms and phase; automatic range conversion, data storage; large screen LCD display, Chinese output, and with printing.



Working Principle:



Due to the use of standard capacitor and tested capacitor synchronous sampling technology, it is not affected by power supply voltage fluctuations; in addition, the measurement process is fully automatic, avoiding errors caused by manual operation, so it has the characteristics of good stability, good repeatability, accuracy and reliability.






Previous: None

Next:Automatic Capacitance and Inductance Tester