III. Technical Indicators
Environmental group: Belongs to Group III instruments in GB6587.1-1986 "General Outline for Environmental Testing of Electronic Measuring Instruments".
Type: Portable Packaging: Aluminum alloy case
Dimensions and weight::
Main unit: 440×300×150 (mm) 5 (kg)
Accessories: 440×300× 80 (mm) 3 (kg)
Working power supply: AC220V ±10% Frequency: 50Hz ±5%
Ambient temperature: -10°C~40°C Relative humidity: ≤85%
Insulation resistance: ≤2MΩ
Dielectric strength: The power input line to the casing can withstand a withstand voltage test of 1.5KV for 1 minute.
Time test range: 1~499.9ms Resolution: 0.01ms Accuracy ≤0.1ms
Speed test range: 15m/s Resolution: 0.01m/s Accuracy ±1% reading 2 digits
Stroke test range: unlimited Resolution: 0.01mm Accuracy ±1% reading 2 digits
Product parameters
1. Input characteristics
Active part:
Voltage measurement range: 0~10V.
Current measurement range: 0~10A.
Passive part:
Voltage measurement range: 0~750V wide range.
Current measurement range: 0~100A, all internal automatic range switching.
2. Accuracy
Voltage: ±0.5%.
Current: ±0.5%.
Power: ±0.5% (CosΦ>0.2), ±1.0% (0.02
3. Working temperature: -10℃~+40℃
4. Charging power supply: AC 160V~260V
5. Insulation:
(1) Insulation resistance between voltage and current input terminals and the casing ≥100MΩ.
(2) The working power input terminal to the casing withstands a power frequency of 2kV (effective value) for 1 minute test.
6. Main unit volume: 32cm×24cm×13cm
7. Weight: 3k
DC power supply selection range: 25-265V/10A Resolution: 1V: Accuracy ≤±1%