Product Description
Program-controlled High Current Generator is a specialized equipment designed and manufactured for power departments and industrial/mining enterprises in electrical equipment tests such as current load tests and temperature rise tests for various switches, current transformers, and other electrical devices.
This series of products adopts split/integrated structure depending on product volume and weight, featuring stepless output current adjustment, balanced current rise, wide load variation range, reliable operation, simple operation, and safety. It is an ideal equipment for current rise or temperature rise tests in industrial and mining enterprises.
Working Principle
After connecting the working power supply, this series of products adjusts the output voltage of the voltage regulator to obtain the required high current for testing.
Program-controlled High Current Generator Technical Parameters
|
Model |
Rated Capacity (KVA) |
Rated Input of Current Generator |
Rated Output of Current Generator |
Impedance Voltage |
No-load Current |
Structure Form |
|||
|
Voltage Regulator |
Current Generator |
Current A |
Voltage V |
Current KA |
Voltage V |
||||
|
SCD-5/1000 |
5 |
5 |
22.7 |
220 |
1 |
5 |
≤8% |
≤6% |
Split |
|
SCD-10/2000 |
10 |
10 |
45.4 |
220 |
1/2 |
10/5 |
≤8% |
≤6% |
Split |
|
SCD-20/4000 |
20 |
20 |
90.9 |
220 |
2/4 |
10/5 |
≤8% |
≤6% |
Split |
|
SCD-25/5000 |
25 |
25 |
113.6 |
220 |
2.5/5 |
10/5 |
≤8% |
≤6% |
Split |
|
SCD-50/10000 |
50 |
50 |
125 |
400 |
5/10 |
10/5 |
≤8% |
≤6% |
Split |
Note: In the "Rated Output of Current Generator", the left side is series connection, and the right side is parallel connection output parameters.
Operating Environment
1. Working power supply: 220V/380V ±10% 50HZ
2. Ambient temperature: -10℃ to 40℃
3. The product should be placed in an environment free from gases, vapors, chemical deposits, dust, dirt, or other explosive media that could seriously affect the insulation of the transformer.
Program-controlled High Current Generator Usage Methods and Precautions
1. Connect the working circuit according to the electrical schematic diagram. The transformer casing and operation console must be properly grounded.
2. Connect the power supply, and the green indicator light on the operation console will illuminate. Press the start button, and the red indicator light will illuminate, at which point the current generator is ready for current rise.
3. Rotate the voltage regulator clockwise evenly, and observe the output current indicator on the operation console until the required high current is reached. To ensure test accuracy, a standard ammeter can be connected in series at the instrument terminals.
4. During the test, if any abnormal condition is found, immediately cut off the power supply, investigate the cause, and then proceed with the test.
5. After the test, the voltage regulator must be returned to zero, press the stop button to cut off the power supply, and then disconnect the working power supply before removing the test wiring to ensure safety.
Complete Product Configuration
1. Operation console: 1 unit
2. Current generator transformer: 1 unit
3. Product certificate: 1 copy
4. Product instruction manual: 1 copy