1. Adopts high-speed 16-bit A/D converter, with stable measurement data and good repeatability.
2. Automatic program-controlled current source technology, with a total of 1000 current gears set in the current source, automatically controlled by the internal microcontroller according to the measured resistance, thereby achieving a relatively wide measurement range and optimal measurement state, without the need for manual current gear switching.
3. Fast response speed, allowing direct switching of the tap changer during measurement, with the instrument automatically prompting and the new resistance value quickly displayed.
4. Highly intelligent design with ingenious and advanced function settings, capable of automatically detecting faults such as loose test leads or broken circuits.
5. Comprehensive protection functions, reliably protecting the instrument from back EMF impact, with automatic discharge indication.
6. Displays measurement current and measurement time.
7. Intelligent power management technology effectively reduces internal heating of the instrument.
8. Can store 120 measurement data sets, with data retained after power-off.
9. All Chinese menu and operation prompts, intuitive and convenient.
Product Features
1. Adopts brand-new power supply technology, with rapid measurement, compact size, and easy use.
2. Large-capacity CPU can store 255 sets of measurement results.
3. Uses typical four-wire measurement method to improve accuracy of resistance measurement (especially low resistance).
4. Comes with a built-in panel-mounted micro printer, capable of printing measurement results in Chinese.
5. Stored results can be viewed and printed.
Technical Specifications
1. Output current: 5A, 10A
2. Measurement range: 5A: 1mΩ~4Ω
10A: 1mΩ~1Ω
3. Resolution: 1μΩ
4. Test accuracy: 0.2 class
5. Operating temperature: -10℃~50℃
6. Operating humidity: 0~80%
7. Power supply: AC 220V±10% 50Hz±1Hz
Usage Parameters
>Measurement range: 0~2000Ω. (Six ranges in total)
>Test current: 5A (20mΩ~2Ω); 0.5A (20Ω); 0.05A (200Ω); 0.005A (2000Ω).
>Resolution: 1μΩ (20mΩ range); 10μΩ (200mΩ range); 0.1mΩ (2Ω range); 1mΩ (20Ω range); 10mΩ (200Ω range); 0.1Ω (2000Ω range).
>Accuracy: 1mΩ~2000Ω (±0.5%)
>Total power consumption: ≤100W
>Operating temperature and humidity: 0℃~40℃; ≤85% RH
>Withstand voltage: AC1.5kV 50HZ 1min
>Power supply: AC220V 50 HZ (±10%)
>Dimensions: 350mm(L)×260mm(W)×140mm(D)
>Weight: approx. 3kg