Tester Features
◆ Simple operation, Chinese display, printing
◆ Convenient use, no conversion needed
◆ The variable frequency dielectric loss tester comes with high voltage, strong anti-interference capability, and short test time advantages
Tester Characteristics
| 1. | Due to the adoption of frequency conversion technology, accurate measurement can be ensured under strong electric field interference. |
| 2. | The instrument uses a Chinese menu operation, and the microcomputer automatically completes the entire measurement process. |
| 3、 | This instrument is also suitable for measuring the tgδ and capacitance of high-voltage electrical equipment in workshops, laboratories, and scientific research units; it also has advantages of convenience, simplicity, and accuracy for insulation oil loss testing. |
| 4、 | This instrument can measure ungrounded or directly grounded high-voltage electrical equipment using positive or reverse connection methods. It can also measure the tgδ of capacitive voltage transformers and the capacitance of main capacitors C1 and C2. |
| 5、 | The instrument is internally equipped with a high-voltage step-up transformer and incorporates safety protection measures such as zero-crossing closing and lightning protection. During the test, it outputs high voltages of different levels from 0.5KV to 10kV, making operation simple and safe. |
Tester Parameters
1. High voltage output: 0.5 to 10kV, with each step increasing by 500V, total 20 steps
High voltage output cable, can be used dragging on the ground
Three frequencies: 45Hz, 50Hz, 55Hz
2. Capacity: 1500VA
3. Accuracy: tgδ: ±(reading*1.0%+0.08%)
Cx: ±(reading*1.5%+5PF)
4. Resolution: tgδ: 0.01% Cx: 1pF
5. Measurement range: 0.1% < tgδ < 50%
3PF< Cx < 60000PF
At 10KV, Cx ≤30000PF
At 5KV, Cx ≤60000PF
6. Power supply: AC 220V ±10% 50 ±1Hz
7. Harmonic adaptation: ≤3%
8. Operating conditions: -15℃ to 50℃, relative humidity <80%
9. Dimensions: 460 (L) ×335 (W) ×340 (H)
10. Weight: 30 kg