The dielectric loss insulation test can effectively detect overall moisture, deterioration, and local defects in the insulation of electrical equipment. It is widely used in electrical manufacturing, installation of electrical equipment, handover, and preventive tests.
This instrument adopts variable frequency power supply technology, utilizing microcontrollers and electronic technology for automatic frequency conversion, analog-to-digital conversion, and data calculation, achieving strong anti-interference capability, fast test speed, high accuracy, and easy operation.
The variable frequency power supply uses a high-power switching power supply, outputting pure sine waves at 45Hz and 55Hz, with automatic voltage boosting, capable of providing up to 10kV voltage; it automatically filters out 50Hz interference, suitable for on-site testing in substations and other environments with high electromagnetic interference.
: Dielectric loss tester, anti-interference dielectric loss tester, fully automatic dielectric loss tester, variable frequency dielectric loss tester, variable frequency dielectric loss and capacitance tester, anti-interference dielectric loss and capacitance tester, fully automatic dielectric loss and capacitance tester
Product Parameters Product Parameters
Technical Parameters
| Measurement Range | Capacitance Value | 3pF ~ 60000 pF/10kV, 60pF ~ 1μF/0.5kV |
| Dielectric Loss Range | 0 ~ 100% unlimited, Resolution: 0.001% | |
| Automatic identification of capacitance, inductance, and resistance test objects | ||
| Maximum Error | Capacitance Accuracy | ± (1.0%×reading ±1 pF) |
| Dielectric Loss Accuracy | ± (1.0%×reading ±0.04%) | |
| Resolution | Capacitance Resolution | Minimum resolvable 0.001 pF |
| Dielectric Loss Resolution | Minimum resolvable 0.001 pF | |
| Test Current Range | 10μA~5A | |
| Internal High Voltage | Set Voltage Range | 0.5~10kV |
| Maximum Output Current | 200mA | |
| Test Frequency | 50Hz single frequency, 45/55Hz automatic dual frequency conversion | |
| Power Supply | 180V ~ 270VAC, 50Hz/60Hz ± 1% (mains or generator supply) | |
| Working Environment | Ambient Temperature | 0 ~ 40℃ |
| Ambient Humidity | ≤ 90%RH, non-condensing | |
| Dimensions | 465×350×360mm 3 | |
| Weight | 27.6kg | |
Note: